ST 031P
ST 031P "PIRANHA" MULTIFUNCTIONAL COUNTERSURVEILLANCE INSTRUMENTS

ST 031P = ST 031 “PIRANHA”+ DIGITAL INTERFASE
that provides the added features of:
• operation with an IBM PC-compatible computer
• control of the scanning receiver
• SOFTWARE UPGRADES
Control of the scanning receiver (AOR8000, 8200, 5000).
The scanning receiver can be controlled while the instrument operates in the HF detector/frequency meter mode, and conductive line scanning analyser mode. The action is based on tuning the receiving frequency of the scanning receiver, to match the frequency of the signal received. This may be performed automatically, when the frequency is registered by the HF detector, or manually by the user. This feature allows prompt checking of the detected signal, aided with the capabilities of a scanning receiver.
Operation with an IBM PC or PC-compatible computer
For operation with an IBM PC or PC-compatible computer, a program specifically developed for the purpose is used, that allows
• the transfer of information from ST 031P's display on to the computer monitor
• the creation of a database of graphic and audio files, that are being generated in the process of operation with ST 031P in real time, or are retrieved from ST 031P's non-volatile memory.
In mode of HF detector/ frequency meter identification of Bluetooth and Wi - Fi signal is added.
For software upgrades (new versions, additional features), connect ST 031 via Serial Port to your PC, and visit the manufacturer’s site; the instrument will be reprogrammed automatically.

Specifications | |
Radio frequency detector-frequency meter | |
Operating frequency range, MHz | 30-2500 |
Sensitivity at input, mV | <1 (30MHz-1000MHz) |
| <4 (1000MHz-1800MHz) |
| <8 (1800MHz-2000MHz) |
Dynamic range, dB | 60 |
Frequency meter sensitivity, mV | <15 |
Frequency measurements accuracy, MHz | ± 0.01 |
Conductive wire lines scanning analyzer | |
Scanning range, MHz | 0.01-15 |
Sensitivity for signal/noise ratio 10 dB, mV | <0.5 |
Scanning increment, kHz | 5(1) |
Scanning speed, kHz/s | 50-1500 |
Band width, kHz | 10 |
Selectivity as per neighboring channel, dB | 30 |
Detection modes | AM, FM |
Allowable mains voltage, V | 600 |
Infrared radiation detector | |
Spectral range, nm | 770-1000 |
Threshold sensitivity, W/Hz1/2 | 10-13 |
Angle of sight, grad | 30 |
Band width of detection, MHz | 3 |
Low frequency magnetic fields detector | |
Frequency range, kHz | 0.3-10 |
Threshold sensitivity, A/(m*Hz2) | 10-5 |
Low frequency differential amplifier | |
Gain, dB | 22±1 |
Input voltage noise, mcV | <2 |
Dynamic range, dB | >70 |
Input impedance, kOhm | >200 |
CMRR, dB | 75 |
Operating frequency range, Hz | 200-8000 |
Maximum input voltage, V | <70 |
Vibro-acoustic converter | |
Frequency range, kHz | 0.3-6 |
Sensitivity, V*s2/m | 1 |
Intrinsic noise within the band of 0.3-3 kHz, uV | 50 |
Acoustic converter | |
Frequency range, kHz | 0.3-8 |
Sensitivity, mV/Pa | >5 |
Oscilloscope and spectrum analyzer | |
Band width, kHz | 22 |
Sensitivity at the input, mV | <10 |
Metering error, % (of the upper limit) | 1 |
Oscillogram output speed, s | 0.2 |
Spectrogram output speed, s | 0.3 |
Power | |
Power supply (DC), V | 6(4 batteries, AA type)/220 |
Maximum consumed current, mA | 300 |
Consumed current in operating mode, mA | 150 |
Dimensions and weight | |
The principal control, processing and indication unit: overall dimensions, mm | 180х97х47 |
The principal control, processing and indication unit: weight, kg | 0.8 |
Complete set: overall dimensions, mm | 350х310х160 |
Complete set: weight, kg | not exceeding |
The complete set of the instrument includes the following components: | |
Name | pieces |
1. The main control processing and indication unit. | 1 |
2. Radio frequency antenna. | 1 |
3. Adapter for conductive wire lines' scanning analyzer. | 1 |
4. Conductive wire lines' differential adapter .* | 1 |
5. Magnetic sensor. | 1 |
6. Infrared sensor. | 1 |
7. Vibro-acoustic sensor. | 1 |
7a. Acoustic sensor. | 1 |
8. Telescopic antenna. | 1 |
9. "Needle" type extensions. | 2 |
10. "220" type extensions. | 2 |
11. "Alligator" clip type extensions. | 2 |
12. Headphones. | 1 |
13. Installation disc with software. | 1 |
14. Cable for connection to IBM PC and scanning receiver. | 1 |
15. Cable for recording of audio information. | 1 |
16. Shoulder belt for the main unit, with a pocket for sensors. | 1 |
17. Main unit support. | 1 |
18. Power supply unit. | 1 |
19. AA type batteries. | 4 |
20. "TEST" monitoring device.* | 1 |