ST031 "PIRANHA"
ST 031 "PIRANHA" MULTIFUNCTIONAL COUNTERSURVEILLANCE INSTRUMENTS

The ST 031 "PIRANHA" multifunctional countersurveillance instrument is intended for implementation of arrangements for detection and localization of special technical means (STM) used for secret acquisition of information, for revealing of natural and artificially created channels for leakage of information as well as for monitoring of information protection quality.
The instrument consists of the Main Control and Indication Unit, and a set of Transducers, and is capable of operating in the following modes:
The information is displayed on a liquid crystal screen with adjustable backlighting.
The instrument is controlled with the aid of a 16-key film keyboard. Sound output is available via headphones or speaker. The instrument allows to process the received low frequency signals in either oscilloscopic mode, or spectrum analyser mode with a digital representation of data. Its non-volatile memory can store up to 99 screen images.
On the screen, help can be displayed, available in both Russian and english.
ST 031 can be powered from either 4 type AA batteries, or a power unit.
ST 031 is a portable unit. For handling and storage a special bag is used, tailored to house all the components in a convenient way. ST 031 "Piranha" is protected by utility patent under the laws of Russian Federation.
Specifications Radio frequency detector-frequency meter Operating frequency range, MHz 30-2500 Sensitivity at input, mV <1 (30MHz-1000MHz) <4 (1000MHz-1800MHz) <8 (1800MHz-2000MHz) Dynamic range, dB 60 Frequency meter sensitivity, mV <15 Frequency measurements accuracy, MHz ± 0.01 Conductive wire lines scanning analyzer Scanning range, MHz 0.01-15 Sensitivity for signal/noise ratio 10 dB, mV <0.5 Scanning increment, kHz 5(1) Scanning speed, kHz/s 50-1500 Band width, kHz 10 Selectivity as per neighboring channel, dB 30 Detection modes AM, FM Allowable mains voltage, V 600 Infrared radiation detector Spectral range, nm 770-1000 Threshold sensitivity, W/Hz1/2 10-13 Angle of sight, grad 30 Band width of detection, MHz 3 Low frequency magnetic fields detector Frequency range, kHz 0.3-10 Threshold sensitivity, A/(m*Hz2) 10-5 Low frequency differential amplifier Gain, dB 22±1 Input voltage noise, mcV <2 Dynamic range, dB >70 Input impedance, kOhm >200 CMRR, dB 75 Operating frequency range, Hz 200-8000 Maximum input voltage, V <70 Vibro-acoustic converter Frequency range, kHz 0.3-6 Sensitivity, V*s2/m 1 Intrinsic noise within the band of 0.3-3 kHz, uV 50 Acoustic converter Frequency range, kHz 0.3-8 Sensitivity, mV/Pa >5 Oscilloscope and spectrum analyzer Band width, kHz 22 Sensitivity at the input, mV <10 Metering error, % (of the upper limit) 1 Oscillogram output speed, s 0.2 Spectrogram output speed, s 0.3 Power Power supply (DC), V 6(4 batteries, AA type)/220 Maximum consumed current, mA 300 Consumed current in operating mode, mA 150 Dimensions and weight The principal control, processing and indication unit: overall dimensions, mm 180х97х47 The principal control, processing and indication unit: weight, kg 0.8 Complete set: overall dimensions, mm 350х310х160 Complete set: weight, kg not exceeding 5
Specifications | |
Radio frequency detector-frequency meter | |
| Operating frequency range, MHz | 30-2500 |
| Sensitivity at input, mV | <1 (30MHz-1000MHz) |
| <4 (1000MHz-1800MHz) | |
| <8 (1800MHz-2000MHz) | |
| Dynamic range, dB | 60 |
| Frequency meter sensitivity, mV | <15 |
| Frequency measurements accuracy, MHz | ± 0.01 |
Conductive wire lines scanning analyzer | |
| Scanning range, MHz | 0.01-15 |
| Sensitivity for signal/noise ratio 10 dB, mV | <0.5 |
| Scanning increment, kHz | 5(1) |
| Scanning speed, kHz/s | 50-1500 |
| Band width, kHz | 10 |
| Selectivity as per neighboring channel, dB | 30 |
| Detection modes | AM, FM |
| Allowable mains voltage, V | 600 |
Infrared radiation detector | |
| Spectral range, nm | 770-1000 |
| Threshold sensitivity, W/Hz1/2 | 10-13 |
| Angle of sight, grad | 30 |
| Band width of detection, MHz | 3 |
Low frequency magnetic fields detector | |
| Frequency range, kHz | 0.3-10 |
| Threshold sensitivity, A/(m*Hz2) | 10-5 |
Low frequency differential amplifier | |
| Gain, dB | 22±1 |
| Input voltage noise, mcV | <2 |
| Dynamic range, dB | >70 |
| Input impedance, kOhm | >200 |
| CMRR, dB | 75 |
| Operating frequency range, Hz | 200-8000 |
| Maximum input voltage, V | <70 |
Vibro-acoustic converter | |
| Frequency range, kHz | 0.3-6 |
| Sensitivity, V*s2/m | 1 |
| Intrinsic noise within the band of 0.3-3 kHz, uV | 50 |
Acoustic converter | |
| Frequency range, kHz | 0.3-8 |
| Sensitivity, mV/Pa | >5 |
Oscilloscope and spectrum analyzer | |
| Band width, kHz | 22 |
| Sensitivity at the input, mV | <10 |
| Metering error, % (of the upper limit) | 1 |
| Oscillogram output speed, s | 0.2 |
| Spectrogram output speed, s | 0.3 |
Power | |
| Power supply (DC), V | 6(4 batteries, AA type)/220 |
| Maximum consumed current, mA | 300 |
| Consumed current in operating mode, mA | 150 |
Dimensions and weight | |
| The principal control, processing and indication unit: overall dimensions, mm | 180х97х47 |
| The principal control, processing and indication unit: weight, kg | 0.8 |
| Complete set: overall dimensions, mm | 350х310х160 |
| Complete set: weight, kg | not exceeding 5 |
The complete set of the instrument includes the following components: Name pieces 1. The main control processing and indication unit. 1 2. Radio frequency antenna. 1 3. Adapter for conductive wire lines' scanning analyzer. 1 4. Conductive wire lines' differential adapter *. 1 5. Magnetic sensor. 1 6. Infrared sensor. 1 7. Vibro-acoustic sensor. 1 7a. Acoustic sensor. 1 8. Telescopic antenna. 1 9. "Needle" type extensions. 2 10. "220" type extensions. 2 11. "Alligator" clip type extensions. 2 12. Headphones. 1 13. Shoulder belt for the main unit, with a pocket for sensors. 1 14. Main unit support. 1 15. Power supply unit. 1 16. AA type batteries. 4 17. "TEST" monitoring device.* 1 18. Technical Description and Operating Manual. 1
| The complete set of the instrument includes the following components: | |
| Name | pieces |
| 1. The main control processing and indication unit. | 1 |
| 2. Radio frequency antenna. | 1 |
| 3. Adapter for conductive wire lines' scanning analyzer. | 1 |
| 4. Conductive wire lines' differential adapter *. | 1 |
| 5. Magnetic sensor. | 1 |
| 6. Infrared sensor. | 1 |
| 7. Vibro-acoustic sensor. | 1 |
| 7a. Acoustic sensor. | 1 |
| 8. Telescopic antenna. | 1 |
| 9. "Needle" type extensions. | 2 |
| 10. "220" type extensions. | 2 |
| 11. "Alligator" clip type extensions. | 2 |
| 12. Headphones. | 1 |
| 13. Shoulder belt for the main unit, with a pocket for sensors. | 1 |
| 14. Main unit support. | 1 |
| 15. Power supply unit. | 1 |
| 16. AA type batteries. | 4 |
| 17. "TEST" monitoring device.* | 1 |
| 18. Technical Description and Operating Manual. | 1 |